Find My SPD โ†’
  1. Home
  2. »
  3. About
  4. »
  5. Quality Assurance
ISO 9001 SPD Manufacturer | Quality Assurance | TrilPeak
Quality Assurance · ISO 9001 Certified · 100% Routine Testing

Every SPD Tested.
Every Batch Traceable.

TrilPeak is an ISO 9001 certified SPD manufacturer operating a three-stage quality system โ€” IQC, IPQC, and OQC โ€” applied to every production run. Every finished surge protective device undergoes 100% routine electrical testing before shipment, with serial number traceability from raw material to packaged product.

View CE Certificates
ISO 9001 Certified 100% Routine Testing IQC ยท IPQC ยท OQC CE ECM Italy Serial Traceability
ISO 9001Certified QMS
100%Routine Electrical Test
3-StageIQC ยท IPQC ยท OQC
ECM ItalyThird-Party CE
24hDocument Delivery
ISO 9001 Certification

ISO 9001:2015 โ€” Quality Management System

TrilPeak holds ISO 9001:2015 certification covering the manufacture and supply of surge protective devices. The quality management system governs incoming material inspection, in-process production controls, finished product testing, and post-delivery corrective action processes.

ISO 9001 certification is maintained through periodic surveillance audits. The certificate and scope documentation are available on request for procurement submissions and supplier qualification reviews.

Certificate Details
StandardISO 9001:2015
ScopeManufacture and sales of surge protective devices
AvailableCertificate ยท On request
CE Certification โ€” Third-Party

ECM Italy CE Certification โ€” Not Self-Declared

TrilPeak's SPDs carry CE marking issued by Ente Certificazione Macchine (ECM), Italy โ€” an independent third-party certification body. ECM independently reviewed TrilPeak's technical documentation and IEC type test reports before issuing certificates.

AC SPD

EN IEC 61643-11:2025

Cert No.0P260312.YTEUD26
Models25 AC models
Valid toMarch 2031
View Full Details →
DC / PV SPD

EN 61643-31:2019

Cert No.0P260312.YTEUD25
Models33 DC/PV models
Valid toMarch 2031
View Full Details →
Quality Control System

Three-Stage Quality Control: IQC · IPQC · OQC

A product cannot advance to the next stage without passing the preceding inspection. IPQC inspectors operate independently of the production line and report directly to the quality department.

IQC โ€” Incoming Quality Control

Raw Materials Verified Before Production

Every incoming material batch is sampled and inspected before entering production. Substandard material is quarantined and rejected before reaching the assembly line.

MOV chip: Varistor voltage (Vn), clamping voltage, energy rating, leakage current
PCB: dimensional tolerance, pad quality, solder mask coverage
Enclosure hardware: dimensional fit, IP rating compliance
Packaging: moisture barrier integrity, labelling accuracy
IPQC โ€” In-Process Quality Control

Inspections at Defined Assembly Intervals

Inspections are conducted at defined intervals during assembly and soldering. Out-of-tolerance findings trigger immediate line hold and root cause investigation.

MOV soldering: joint quality, orientation, spacing
Terminal and wiring assembly: torque consistency
Thermal disconnector: mechanical function check
Pre-potting visual inspection on sealed units
OQC โ€” Outgoing Quality Control

100% Electrical Test โ€” Every Unit, Every Batch

Every unit undergoes 100% routine electrical testing before packaging. This is not sampling โ€” it is applied to the full production quantity. Batches with failures are held pending root cause analysis.

Voltage protection level (Up) โ€” at rated impulse current
Follow current extinguishing โ€” Type 1 units
Thermal disconnector: mechanical and electrical activation
Insulation resistance โ‰ฅ 1Mฮฉ at 500V DC
100% Routine Test ParameterStandard ReferenceResult Required
Voltage protection level (Up)IEC 61643-11 / IEC 61643-31โ‰ค Declared Up value
Follow current extinguishingIEC 61643-11 (Type 1)Confirmed extinction
Thermal disconnector functionIEC 61643-11Mechanical + electrical pass
Insulation resistanceIEC 61643-11โ‰ฅ 1Mฮฉ at 500V DC
Continuity โ€” PE pathIEC 61643-11Confirmed continuity
Visual & mechanicalInternal QC specLabel, DIN fit, indicator pass
Serial Number Traceability

Full Batch Traceability โ€” Raw Material to Shipped Unit

Every TrilPeak SPD carries a unique serial number linking the finished product to its complete production batch record. Records are retained for a minimum of five years.

๐Ÿงช

Raw Material Linkage

MOV chip batch number and raw material intake record โ€” traceable to the source material lot used in production.

โš™๏ธ

Production Records

Production date, line assignment, and IPQC inspection result linked to each serial number range.

โšก

OQC Electrical Data

Per-unit OQC test measurements stored against serial number โ€” voltage protection level, insulation resistance, disconnector result.

๐Ÿšš

Shipment Reference

Shipment order number and packing list reference linked to serial number range for customs and project documentation.

๐Ÿ“‹

Warranty & Recall Support

Traceability enables individual unit warranty claim verification and field recall management without recalling entire batches.

๐Ÿ“…

5-Year Record Retention

All batch records, test data, and traceability links retained for a minimum of five years post-shipment.

Quality Documentation

Complete Documentation for Procurement & Tenders

Full documentation set for B2B procurement, EU tender submissions, and import clearance. All documents delivered within 24 hours of request.

ISO 9001 Certificate
QMS scope ยท surveillance audit cycle
On request
CE Certificate โ€” AC SPD
ECM Italy ยท No. 0P260312.YTEUD26 ยท EN IEC 61643-11:2025
Download PDF →
CE Certificate โ€” DC/PV SPD
ECM Italy ยท No. 0P260312.YTEUD25 ยท EN 61643-31:2019
Download PDF →
EU Declaration of Conformity (DoC)
LVD + EMC + RoHS ยท All certified models
24h delivery
IEC Type Test Reports
EN IEC 61643-11:2025 / EN 61643-31:2019
24h delivery
Routine Test Data (batch-specific)
Per-unit OQC results ยท Available for OEM orders
With OEM order
Product Datasheets โ€” English
All certified models ยท Specifications + wiring diagrams
On request
Factory Audit Appointment
QMS review ยท production floor ยท live OQC observation
By arrangement
Need documents for a tender, project approval, or customs clearance? Our team responds within 24 hours.
FAQ

Quality Assurance FAQ

All FAQs →

Is 100% routine testing standard or an additional service?

It is standard. Every unit in every production batch is electrically tested before packaging. There is no additional charge and no option to waive it. Batch-specific test data is available for OEM orders on request.

Does TrilPeak provide test reports with OEM orders?

Yes. Batch-specific routine test data and a copy of the applicable CE certificate are included with every OEM production order. IEC type test reports are available within 24 hours on request.

Can I audit TrilPeak's factory and quality system?

Yes. Factory audits โ€” including quality system review, production floor walkthrough, and live OQC observation โ€” can be arranged. Third-party inspection by SGS, Bureau Veritas, or Intertek is also welcomed. Contact us to schedule →

What happens if a unit fails OQC?

The unit is removed from the batch, assigned a failure code, and sent to the engineering team for root cause analysis. The batch is held until the failure is understood. Failed units are never reworked and re-released without a full re-test cycle.

ISO 9001 ยท CE Certified ยท 24h Response

Request Quality Documentation for Your Project

CE certificates, ISO 9001 certificate, EU Declaration of Conformity, IEC type test reports, and datasheets โ€” delivered within 24 hours.

ISO 9001:2015 certified QMS ยท 100% routine electrical testing
CE certified by ECM Italy ยท EN IEC 61643-11:2025 ยท EN 61643-31:2019
Full serial number traceability ยท batch records retained 5 years
Factory audit appointments available ยท third-party inspection welcomed
Contact Us
Scroll to Top
Subscribe Form
Contact US
Inquire Now